SMT Reflow Process Window: Solder Paste Maximum Slope vs. Ramp (or Average) Rate

Included in a solder paste‘s Product Data Sheet, among other things, are general guidelines which aid the customer in designing an SMT reflow profile. The data sheet gives general recommendations, for time above liquidus, peak temperature, and ramp rate.

Beispiel:

Indium8.9 Profile Recommendations

Figure 1: Example shown Indium8.9 flux with SAC lead-free alloy

The reason for approaching this subject is that often there has been some confusion in regards to the difference between max slope (a category reported on most profiling software) and the ramp rate listed on a data sheet.

Max Slope

Figure 2: Max Slope

Die maximale Steigung wird sehr oft in der ersten Zone erreicht, wenn die Leiterplatte von der Umgebungstemperatur in den Ofen gelangt. In den meisten Fällen beträgt die Einstellung der ersten Zone des Ofens 100°C oder mehr. Die Temperaturänderung zwischen der Umgebungstemperatur und der ersten Zone beträgt dann mindestens 75°C (unter der Annahme, dass die Umgebungstemperatur 25°C beträgt), und so ist es leicht zu erkennen, dass die größte Temperaturänderung (maximale Steigung) in den meisten Fällen in der ersten Zone zu finden ist

Der Schwerpunkt der maximalen Steigung liegt eher auf dem Bauteil, um einen thermischen Schock zu vermeiden; normalerweise wird 3°C/s als Obergrenze empfohlen.

Ramp or Average Rate

Figure 3: Ramp or Average Rate

The ramp rate may be better described as the rate (change in temperature over time) from ambient (room temperature) to peak. And is more practically used in a ramp to spike type profile

From the view point of the solder paste, the lower the ramp rate the better, usually 1-2°C/s. This is to drive off volatiles and help minimize solder defects such as solder balling, solder beading, and tombstoning. This rate becomes even more important as the solder paste deposit continually decreases in size, as we move to 0201’s and smaller discrete components and from 0.5mm pitch area array packages to 0.4mm and smaller. Due to this miniaturization, the observance of graping and head-in-pillow have become more common. The reflow process window is becoming very narrow and this attribute (ramp rate) has become as important as time above liquidus and peak temperature.

I’d love to discuss this with you, if this topic is affecting your SMT process. If you’d like, feel free to contact me.